In the Brighton area, Accu-Temp Heating & Air Conditioning is well known for providing exceptional ac repair, installation, and service. The people we send out to serve you are also top notch, something you'll see in their reviews below. Everyone you deal with at our company has the goal of making sure your experience with us will be so good you'll call us every time you need help. You can feel confident working with Accu-Temp Heating & Air Conditioning because we stand behind our work and comply with all local codes. This is why, as you can see by the map and reviews below, we are rated so highly for Furnace Repair and Air Conditioner Repair in Brighton MI (31). Call us today at (517) 548-1555!Your Best Choice for Furnace Repair and Air Conditioner Repair in Brighton MI (31)
Boiler tune up and air conditioner tune up
Did a furnace and AC tune up. I cleaned the burners flame sensor checked the air filter and wp, cleared the drains and all hoses inside the furnace. Ran a combustion analysis. Cleaned the condenser coil tested startup components checked the refrigerant charge and both units are operating properly at this time
Did a furnace and AC tune up on a Lennox g60 and a Lennox hsx I cleaned the burners flame sensor and cleared the pressure switch hose tested the ignitor and all limits and safeties, changed the water panel and tested the humidifier drain and operation. Ran a combustion analysis. I cleaned the condenser coil tested startup components and checked the refrigerant charge and both units are operating properly at this time
Replace bad inducer relay and test all system operations.
Did an a/c tune up on a xc16 I cleaned the condenser coil cleared the drain checked the air filter tested the startup components and checked the refrigerant charge and this unit is operating properly at this time
Lennox furnace and A/C tune up
Did a furnace tune up on a Lennox ml195 I cleaned the burners and flame sensor tested the ignitor and all limits and safeties, cleared the drains and all hoses inside the furnace, checked the humidifier pad and thermostat batteries, tested the humidifier drain and operation, ran a combustion analysis and this furnace is operating properly at this time
Repair zone problems on a lennox harmony system.
Lennox hs29 air conditioner tune up
Did a furnace and AC tune up on a Lennox G61MPV and Bryant SS2AN changed the air filter and water panel cleaned the burners, flame sensor drains and condenser coil. Tested startup components and checked the refrigerant charge and ran a combustion analysis and both units are operating properly at this time
Lennox sl280 furnace tune up and lennox air conditioner xc13 tune up.
Gas line to stove.
Did a furnace tune up on a Lennox G61MP I checked the thermostat batteries and air filter, cleared the drain and all hoses inside the furnace I tested the ignitor and all limits and safeties cleaned the burners and flame sensor ran a combustion analysis and this furnace is operating properly at this time
Installed a high efficiency Lennox 80% 2 stage variable speed gas SL28UH090V48B-04 furnace aprilaire humidifier
Did a furnace tune up on a el296 I changed the air filter and wp cleared and flushed drain lines. Cleared vacuum hoses cleaned the burners and flame sensor tested the ignitor ran a combustion analysis and this furnace is operating properly at this time
Did a furnace tune up on a Lennox G61MP I cleaned the burners flame sensor and burner orifices, cleared all hoses and the drains, tested the ignitor checked the amp draws changed the thermostat batteries. Ran a combustion test, unit was slightly under fired I adjusted the gas pressure as needed and this unit is operating properly at this time
Did a furnace tune up on a Lennox el180 I cleaned the burners flame sensor and burner orifices cleared all hoses inside the furnace, tested the ignitor checked the amp draws, changed the water panel. Ran a combustion test and this furnace is operating properly at this time
Did a furnace tune up on a Lennox el195 I changed the air filter cleared all hoses inside the furnace visually inspected all wiring,tested the ignitor checked the amp draws cleaned the burners flame sensor and burner orifices. Ran a combustion analysis. This unit is operating properly at this time.
Did a furnace tune up on a Lennox el180 I changed the air filter and water panel, cleared all hoses inside the furnace visually inspected all wiring inside the furnace, tested the ignitor, checked the amp draws cleaned the burners flame sensor and burner orifices ran a combustion test and this furnace is operating properly at this time
Did a furnace tune up on a Lennox el195 I changed the air filter cleaned the burners flame sensor and burner orifices tested the ignitor checked the amp draws on all motors, cleared the furnace drain and all hoses inside the furnace ran a combustion test and this unit is operating properly at this time.
Did a furnace tune up on a Lennox G40 I cleaned the flame sensor, burners and burner orifices. Changed the air filter, checked the thermostat batteries. Cleared all hoses inside the furnace. Tested the ignitor checked the amp draws. Ran a combustion test and this furnace is operating properly at this time.