In the Brighton area, Accu-Temp Heating & Air Conditioning is well known for providing exceptional ac repair, installation, and service. The people we send out to serve you are also top notch, something you'll see in their reviews below. Everyone you deal with at our company has the goal of making sure your experience with us will be so good you'll call us every time you need help. You can feel confident working with Accu-Temp Heating & Air Conditioning because we stand behind our work and comply with all local codes. This is why, as you can see by the map and reviews below, we are rated so highly for Furnace Repair and Air Conditioner Repair in Brighton MI (27). Call us today at (517) 548-1555!Your Best Choice for Furnace Repair and Air Conditioner Repair in Brighton MI (27)
Repair wire connections and charge air conditioning system.
Performed a double utility tune up on a Lennox and a Rheem, I replaced both air filters and the humidifier pad. Cleared all drains and all hoses inside both units tested the humidifier ignitors and all limits and safeties. Checked all motors amp draws. Cleaned the burners and flame sensors. Ran a combination test on each unit. Both units start and run properly at this time
Performed annual preventative maintenance on a Lennox sl280, I replaced the air filter and water panel, tested the humidifier ignitor and all limits and safeties, cleared all drains and vac ports in the unit, cleaned the burners and flame sensor checked all motors amp draws and Rana combustion test and this unit is operating properly at this time
Annual furnace maintenance, air filter, thermostat batteries replacement.
Installation of a Lennox slp98 furnace with humidifier,air cleaner and s-30 Wi-Fi t-stat
Performed preventative maintenance on a York PS8B12, homeowner maintains filter humidifier pad and thermostat batteries. I cleared all the vac ports, tested the ignitor and all limits and safteties. Checked all motors amp draws cleaned the burners and flame sensor and ran a combustion test and this unit starts and runs properly at this time
Heat run
State water heater installation.
Clean flame sensor and test, Lennox G61
Performed annual comprehensive maintenance on a Lennox slp98. I cleared all the drains and hoses inside the unit replaced the air filter and water panel. Cleaned the burners and flame sensor tested humidifier ignitor and all limits and safeties. Checked all motors amp draws and ran a combustion test. This unit starts and runs properly at this time
Installation of a Lennox el180 furnace with air cleaner and t-stat
Amana furnace tune-up
Performed annual preventative maintenance on a Lennox slp98 I replaced the air filter and water panel cleared all drains and hoses inside the furnace tested the humidifier ignitor and all limits and safeties cleaned the burners and flame sensor checked all motors amp draws and ran a combustion test and this unit starts and runs properly at this time
Performed annual maintenance on a Lennox el180 I cleared the drains and all hoses inside the furnace replaced the thermostat batteries air filter and water panel tested the humidifier gnitor and all limits and safeties cleaned the burners and flame sensor checked all motors amp draws ran a combustion test and this unit starts and runs properly at this time
Performed annual preventative maintenance on an Lennox el195 I replace the thermostat batteries air filter and water panel, cleared all drains and all hoses inside unit tested the humidifier ignitor and all limits and safeties cleaned the burners and flame sensor checked all amp draws and ran a combustion test and this unit starts and runs properly at this time
No heat call found failed ignitor, replaced ignitor, water panel for the humidifier tested operation and cleared the drain and all hoses inside unit. Replaced the air filter checked thermostat batteries. Unit starts and runs properly at this time
No heat call, found a blocked vacuum port to a pressure switch, cleared hose. Unit starts and runs properly at this time.
Furnace maintenance and tune up. Install gas shut off.
Lennox high efficiency furnace tune
Performed consumers energy diagnostic tune up with a rebate on a Lennox ML180 I ran a pre service combustion test. I checked the thermostat batteries replaced the air filter, cleared all hoses inside the furnace tested the ignitor and all limits and safeties checked all motors amp draws cleaned the burners flame sensor. Ran post service combustion test and this unit is operating properly at this time.
Performed annual comprehensive preventative maintenance on a carrier 80% furnace. I checked the thermostat batteries air filter and water panel. Cleared all drains and all hoses inside the furnace tested the humidifier ignitor and all limits and safeties. Checked all motors amp draws. Cleaned burners and flame sensor and ran a combustion test and this unit is operating properly at this time
Performed annual comprehensive preventative maintenance on a Rheem 80% furnace. I replaced the thermostat batteries ,air filter and water panel. Cleared the humidifier drain and all hoses inside the furnace tested the humidifier ignitor and all limits and safeties cleaned the burners and flame sensor ran a combustion test checked the motors amp draws and this unit starts and runs properly at this time
Adjust and time a Coleman DGAA furnace.
Performed annual comprehensive preventative maintenance on a Lennox el180 I cleared the humidifier drain and all hoses inside the furnace checked the air filter tested the humidifier ignitor and all limits and safeties cleaned the burners and flame sensor checked all motors amp draws ran a combustion test and this unit starts and runs properly at this time
Gas furnace tune up. Annual maintenance tune up on Bryant gas furnace